Accepts: Mono-Si & Poly-Si c-Si PV panels, broken or whole, framed or unframed.
Prohibited: Thin-film (CdTe/CIGS), hazardous chemicals, moisture-laden industrial sludge.
Designed to exceed industrial safety, energy recuperation, and metallurgical purity requirements.
Patented 120°C low-temp peeling recovers intact glass without EVA polymer degradation.
Continuous oxygen-free tunnel furnace operates 24/7 with zero open flame and self-sustaining heating.
Multi-stage dry electrostatic sorting yields separate clean fractions of copper, silver, and silicon.
Negative pressure off-gas purification system with rapid spray quench suppresses dioxin reformation.
| Parameter Item / Specification | Engineering Standard / Technical Value |
|---|---|
| Target Feedstock | Crystalline Silicon (c-Si) Single-Glass & Bifacial Double-Glass Panels (Width: 800 - 1,300 mm) |
| Capacity | 1-3 t/h (Mechanical Line) | 30-100 t/d (Thermal Tunnel Kiln Line, 15-20 min/panel) |
| Clean Glass Yield | ≥ 95-98% Recovery Rate (Purity ≥ 98%) |
| Silicon Wafer Recovery | ≥ 95-98% Recovery Rate (Purity ≥ 98%) |
| Copper Ribbon Recovery | 95-98% Recovery Rate (Purity ≥ 98%) |
| Silver (Ag) Recovery Rate | ≥ 95% High-Purity Precious Metal Recovery |
| Pyrolysis Working Temperature | 550 - 650°C (Low-oxygen atmosphere O₂ ≤ 4%) |
| Thermal Destruction | Integrated TO furnace operates at ≥ 850°C (residence time ≥ 2s) |
| Emission Standard | Dioxin < 0.1 ng-TEQ/m³ (Rapid quench bypasses 400-250°C window, EU 2010/75/EU Compliant) |
| Automation Level | Siemens S7-1500 PLC + SCADA Control Console |
From raw material pilot trials at our Zhengzhou testing base to ocean shipping, civil foundation guidance, on-site mechanical erection, and environmental acceptance.
Send sample feedstock for pilot test runs and ICP elemental analysis.
Complete plant layout, loading docks, power distribution, and foundation design.
Continuous running tests, pressure testing, and dynamic balancing before shipment.
Senior engineers dispatched for mechanical assembly, DCS tuning, and operator training.
Specialized continuo...